Surgical Face Masks & Respirators

Have any questions or would like help placing an order?

Surgical Face Masks & Respirators
Platinum Health Supply Group’s Range of surgical masks offer affordable and comfortable protection in all environments.
Intended to cover the user's mouth, nose and chin. Provides a physical barrier to prevent pathogenic microorganisms, body fluids, particulate matter, etc. from passing directly.
Unit of Measure:
50 Per Box
Medical Compliance:
TGA Listing Number This product is listed as a Medical Device Included Class 1 (TGA available upon request.
General Features:
- Meets standard ASTM F2100-11 level 3 (bacterial filtration efficiency – BFE, differential pressure – Delta P)
- One size fits all
- Low breathing resistance for maximum comfort and prolonged wear
- Adjustable nose bridge for a personalised fit
- Non-sterile
- Single-use
- Retail packaging
- Latex-free
- Flame resistant
- 50 masks per box
General Information:
A surgical face mask is a disposable face mask worn over the nose and mouth to help protect against the inhalation of airborne particles and to help prevent the spread of unhealthy airborne particles. Surgical Masks are tested against their Bacteria Filtration Efficiency (BFE), Particular-Filtration Efficiency (PFE), Fluid Resistance Penetration (mmHg) and, Breathability (Delta P).
Unlike other cloth face coverings, a medical face mask is very carefully designed and manufactured to ensure that it remains effective at the prevention of spreading disease but not of minimising any respiratory distress a person may feel due to heavy pollution in the air.
Unlike general 3 Ply Face Masks, Surgical Masks are protective for General Public, Vulnerable Individuals, Medical and Health Care Workers, as well as Front Line Workers.
When wearing these mask’s, the user may limit their exposure to smoke, pollution, concrete/ sawdust, water/ virus particles and some vapours, and Bacteria.
Technical Information:
BACTERIAL FILTRATION EFFICIENCY (BFE)
With a Bacterial Filtration Efficiency (BFE) of greater than 99% for media greater than 3 microns, this mask provides superior protection from potential infection.
BFE is an independent test conducted by approved Independent testing facilities that measure the effectiveness of face mask materials to filter out bacteria.
PARTICULATE FILTRATION EFFICIENCY (PFE)
The super high Particulate Filtration Efficiency (PFE) material filters >99% of particles greater than 0.1 microns. When securely fitted, the mask helps to provide an effective barrier to particulate matter from laser plumes and electrocautery procedures.
PFE measures the effectiveness of the mask material to filter particulate matter.
BREATHABILITY (DELTA P)
The mask design provides excellent breathability and low delta P (≤2.8) ensuring coolness and comfort even when worn for an extended period.
Delta P, also conducted by approved Independent testing facilities, is a test that measures the breathability of mask materials, ranking masks on comfort and coolness for the surgical mask wearer. The lower the figure, the cooler and more comfortable the mask.
FLUID RESISTANCE
The Super Fluid Resistant three-ply layer design provides optimum fluid resistance (120mmHg) – Level 2 and (160mmHg) – Level 3, thus minimising the risk of infection through strikethrough.
Fluid resistance is measured in accordance with ASTM F2101-15 | EN 14683:2014 standard test method for resistance of medical face masks to penetration by synthetic blood at 16.0kPa pressure.
International Standards:
- ISO 22609:2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)
- AS/NZS 4381:2015 'Single-use face masks for use in health care'
- ASTM F2100 - 19 Standard Specification for Performance of Materials Used in Medical Face Masks
- S. National Institute of Occupational Safety and Health (NIOSH) 42 CFR Part 84 Respiratory Protective Devices (in relation to products labelled with N-, R- and P- classification at 95, 99 and 99.9% filter efficiency)
- AS ISO 16900.3 2015 Respiratory protective devices - Methods of test and test equipment Determination of particle filter penetration
- AS NZS 1716:2012 Respiratory protective devices (in relation to products labelled with P1/P2/P3 class filter efficiency)
- EN 149:2001 + A1 Respiratory protective devices- Filtering half masks to protect against particle – Requirements, testing, marking (in relation to products labelled with FFP1, FFP2 and FFP3 classification)
- GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying particle respirator (in relation products labelled with the filter element grades types KN and KP 90/95/100 filter elements)
- ISO 22609: 2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood
- EN 14683:2019 Medical face masks - Requirements and test methods
- AS NZS 1715:2009 Selection, use and maintenance of respiratory protective equipment
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Ultra Health Level 2 Surgical Mask - Earloop
General Description:
Platinum Health Supply Group's Range of surgical masks offer affordable and comfortable protection in all environments.
Intended to cover the user's mouth, nose and chin. Provides a physical barrier to prevent pathogenic microorganisms, body fluids, particulate matter, etc. from passing directly.
Product Size:
50 x Disposable Level 2 Surgical Mask - Ear-loop Per Box
20x 50 Units Boxes per carton
1000 Units per carton
Medical Compliance:
TGA Listed Product - This product is listed as a Medical Device Included Class 1
General Features:
- Meets standard ASTM F2100-11 level 2 (bacterial filtration efficiency - BFE, differential pressure - Delta P)
- One size fits all
- Low breathing resistance for maximum comfort and prolonged wear
- Adjustable nose bridge for a personalised fit
- Non-sterile
- Single-use
- Latex-free
- Flame resistant
- 50 masks per box
General Information:
A surgical face mask is a disposable face mask worn over the nose and mouth to help protect against the inhalation of airborne particles and to help prevent the spread of unhealthy airborne particles. Surgical Masks are tested against their Bacteria Filtration Efficiency (BFE), Particular-Filtration Efficiency (PFE), Fluid Resistance Penetration (mmHg) and, Breathability (Delta P).
Unlike other cloth face coverings, a medical face mask is very carefully designed and manufactured to ensure that it remains effective at the prevention of spreading disease but not of minimising any respiratory distress a person may feel due to heavy pollution in the air.
Unlike general 3 Ply Face Masks, Surgical Masks are protective for General Public, Vulnerable Individuals, Medical and Health Care Workers, as well as Front Line Workers.
When wearing these mask's, the user may limit their exposure to smoke, pollution, concrete/ sawdust, water/ virus particles and some vapours, and Bacteria.
Technical Information:
BACTERIAL FILTRATION EFFICIENCY (BFE)
With a Bacterial Filtration Efficiency (BFE) of greater than 99% for media greater than 3 microns, this mask provides superior protection from potential infection.
BFE is an independent test conducted by approved Independent testing facilities that measure the effectiveness of face mask materials to filter out bacteria.
PARTICULATE FILTRATION EFFICIENCY (PFE)
The super high Particulate Filtration Efficiency (PFE) material filters >99% of particles greater than 0.1 microns. When securely fitted, the mask helps to provide an effective barrier to particulate matter from laser plumes and electrocautery procedures.
PFE measures the effectiveness of the mask material to filter particulate matter.
BREATHABILITY (DELTA P)
The mask design provides excellent breathability and low delta P (≤2.8) ensuring coolness and comfort even when worn for an extended period.
Delta P, also conducted by approved Independent testing facilities, is a test that measures the breathability of mask materials, ranking masks on comfort and coolness for the surgical mask wearer. The lower the figure, the cooler and more comfortable the mask.
FLUID RESISTANCE
The Super Fluid Resistant three-ply layer design provides optimum fluid resistance (120mmHg) - Level 2 and (160mmHg) - Level 3, thus minimising the risk of infection through strikethrough.
Fluid resistance is measured in accordance with ASTM F2101-15 | EN 14683:2014 standard test method for resistance of medical face masks to penetration by synthetic blood at 16.0kPa pressure.
International Standards:
- ISO 22609:2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)
- AS/NZS 4381:2015 'Single-use face masks for use in health care'
- ASTM F2100 - 19 Standard Specification for Performance of Materials Used in Medical Face Masks
- S. National Institute of Occupational Safety and Health (NIOSH) 42 CFR Part 84 Respiratory Protective Devices (in relation to products labelled with N-, R- and P- classification at 95, 99 and 99.9% filter efficiency)
- AS ISO 16900.3 2015 Respiratory protective devices - Methods of test and test equipment Determination of particle filter penetration
- AS NZS 1716:2012 Respiratory protective devices (in relation to products labelled with P1/P2/P3 class filter efficiency)
- EN 149:2001 + A1 Respiratory protective devices- Filtering half masks to protect against particle – Requirements, testing, marking (in relation to products labelled with FFP1, FFP2 and FFP3 classification)
- GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying particle respirator (in relation products labelled with the filter element grades types KN and KP 90/95/100 filter elements)
- ISO 22609: 2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood
- EN 14683:2019 Medical face masks - Requirements and test methods
- AS NZS 1715:2009 Selection, use and maintenance of respiratory protective equipment
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
N95 P2 Flat Fold Respirator Australian Made provides excellent protection. It provides single-use, disposable respiratory protection to protect both the wearer and non-wearer from the transfer of microorganisms, body fluids, and particulate material.
- Surpassing American N95 Standard
- Features a 4 layer design to provide the maximum level of fluid resistance.
- P2/N95 respirator particulate respirator and provides high efficiency without valve
- Industrial quality disposable respirator mask with high-efficiency bacteria filtration
- Ideal for flu/pandemic outbreak protection
- Certified for AS/NZS 1716:2012 (certificate from Test Safe available), EN149:2001, and SANS 50149:2003
- Duckbill design with double elastic straps and a metal nose bridge.
- Low breathing resistance with high filtration efficiency.
- An adjustable nose piece and inner foam provide a custom seal.
- 160mmHg Surgical respirator
- BFE>99.7
- PFE>99.6
- Made in Australia
Features:
- 10 Per Box
- Size: Universal
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
The 1870 healthcare respirator is designed to help provide respiratory protection for the wearer against certain airborne particles. It meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a disposable particulate respirator, it is intended to reduce wearer exposure to certain airborne particles including those generated by electro cautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and splatter of blood and other infectious materials.
The 1870 particulate respirator is a personal protective equipment (PPE) that is primarily intended to protect the health care workers by reducing exposure to harmful airborne particles which are small enough to be inhaled – typically particles less than 100 microns in size. These include airborne particles that may contain biological material e.g., Bacillus anthracis, Mycobacterium tuberculosis, mold and the virus that causes severe acute respiratory syndrome (SARS), and Influenza. Proper selection, training and use are essential for the respirator to adequately protect the wearer from certain airborne contaminants. Warning: Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of RPE. Details regarding performance and limitations are set out on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1715:2009 Standard. Misuse can result in sickness or death. For more information, see your supervisor or contact an Occupational Hygienist, Safety professional or 3M TechAssist Helpline – Australia 1800 024 464 / New Zealand 0800 364 357.
- NIOSH certified N95
- Meets CDC guidelines for Mycobacterium tuberculosis exposure control
- Bacterial Filtration Efficiency (BFE) less than 99 percent according to ASTM F2101
- Fluid resistant according to ASTM F1862 at 160mm Hg
- Respirator contains no components made from natural rubber latex
- Red colored head strap for health care use.
- Mold nose clip to wearer’s nose shape to help reduce eyewear fogging and ensure a better seal and fit
Suggested Applications:
- Peripheral and midline venous catheters
- Central venous catheters (including subclavian, jugular, femoral and PICCs)
- Implanted infusion devices (ports)
- Dialysis catheters
- Pulmonary artery catheters
- Arterial catheters
- Laboratory testing has proven 3M Tegaderm and Tegaderm HP Transparent Dressings provide a viral (HIV-1 and HBV) barrier while dressings remain intact without leakage.
Specifications:
Code |
3M1870 |
Aerosol Type |
Non-Oil |
Australia and New Zealand Compliance Standards |
N95 |
Boxes per Case |
6 |
Braided Comfort Strap |
No |
Brand |
Aura |
Cartridge or Filter Induced |
Yes |
Exhalation Valve |
No |
Faceseal/Nosefoam |
Nosefoam |
Flame Resistance (ASTM) D2859-96 |
No |
Flammability Rating |
Class 1 |
Fluid Resistant (ASTM F1862) |
Yes |
Individually Wrapped |
Yes |
Model |
1870 plus |
Natural Rubber Latex Component |
No |
Number Per Box |
20 |
Packaging |
Bulk Case |
Product Color |
White |
Product Type |
Healthcare Respirator |
Respirator Style |
Flat Fold |
Strap Attachment Type |
Stapled |
Packaging |
20 Units Per Box 12 Boxes Per Case |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
N95 P2 Flat Fold Respirator Australian Made provides excellent protection. It provides single-use, disposable respiratory protection to protect both the wearer and non-wearer from the transfer of microorganisms, body fluids, and particulate material.
- Surpassing American N95 Standard
- Features a 4 layer design to provide the maximum level of fluid resistance.
- P2/N95 respirator particulate respirator and provides high efficiency without valve
- Industrial quality disposable respirator mask with high-efficiency bacteria filtration
- Ideal for flu/pandemic outbreak protection
- Certified for AS/NZS 1716:2012 (certificate from Test Safe available), EN149:2001, and SANS 50149:2003
- Duckbill design with double elastic straps and a metal nose bridge.
- Low breathing resistance with high filtration efficiency.
- An adjustable nose piece and inner foam provide a custom seal.
- 160mmHg Surgical respirator
- BFE>99.7
- PFE>99.6
- Made in Australia
Features:
- 10 Per Box
- Size: Universal
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Description:
P2 respirators are a respiratory protective device intended to protect the wearer from airborne particles. When fitted correctly, the respirator forms a seal around the mouth and nose and can filter a minimum of 94% of airborne particulates.
Features and Benefits:
- AS/NZS 1716:2012 compliant
- Particulate filtration efficiency (PFE) >= 94%
- 2 adjustable head loop straps for better securement
- Single use
- Individually wrapped
- Malleable nose strip with moisture trapping foam for comfort
Product Data:
- 20cm (L) x 16cm (W)
- 4-layer construction
- Latex free
- Non-sterile
- ARTG 350735
Fitting Instructions:
- Place the respirator over your face with the nose piece over the nasal bridge. Position the lower headband at the base of the skull and the upper headband across the crown. Make sure your lower chin is also covered. Tighten or lengthen the head loop straps if required. Do not cross the head loops over as this reduces the fit.
- Mold the nose strip to the shape of your nose to ensure it fits your face comfortably and creates a seal. If you wear glasses, ensure the fit across the nose is snug to minimize fogging.
- Inhale and exhale sharply to check for any leakage. Re-adjust the respirator nose strip & headbands if necessary to ensure there is no leakage.
Personal Protection Equipment:
Code |
54-409D |
Description |
P2 Respirator, Head loop |
Size(cm) |
20cm x 16cm |
Sterile/Non-Sterile |
Non-sterile |
Pcs Per Inner Box |
90pcs |
Inners Per Carton |
12 Boxes |
Total Pcs per Carton |
1080pcs |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Platinum Health Supply Group's Range of surgical masks offer affordable and comfortable protection in all environments.
Intended to cover the user's mouth, nose and chin. Provides a physical barrier to prevent pathogenic microorganisms, body fluids, particulate matter, etc. from passing directly.
Product Size:
50 x Disposable Black Level 2 Surgical Mask Ear-loop Per Box
40x 50 Units Boxes per carton
2000 Units per carton
Medical Compliance:
TGA Listing Number - This product is listed as a Medical Device Included Class 1
General Features:
- Meets standard ASTM F2100-11 level 2 (bacterial filtration efficiency BFE, differential pressure Delta P)
- One size fits all
- Low breathing resistance for maximum comfort and prolonged wear
- Adjustable nose bridge for a personalised fit
- Non-sterile
- Single-use
- Latex-free
- Flame resistant
- 50 masks per box
General Information:
A surgical face mask is a disposable face mask worn over the nose and mouth to help protect against the inhalation of airborne particles and to help prevent the spread of unhealthy airborne particles. Surgical Masks are tested against their Bacteria Filtration Efficiency (BFE), Particular-Filtration Efficiency (PFE), Fluid Resistance Penetration (mmHg) and, Breathability (Delta P).
Unlike other cloth face coverings, a medical face mask is very carefully designed and manufactured to ensure that it remains effective at the prevention of spreading disease but not of minimising any respiratory distress a person may feel due to heavy pollution in the air.
Unlike general 3 Ply Face Masks, Surgical Masks are protective for General Public, Vulnerable Individuals, Medical and Health Care Workers, as well as Front Line Workers.
When wearing these mask's, the user may limit their exposure to smoke, pollution, concrete/ sawdust, water/ virus particles and some vapours, and Bacteria.
Technical Information:
BACTERIAL FILTRATION EFFICIENCY (BFE)
With a Bacterial Filtration Efficiency (BFE) of greater than 99% for media greater than 3 microns, this mask provides superior protection from potential infection.
BFE is an independent test conducted by approved Independent testing facilities that measure the effectiveness of face mask materials to filter out bacteria.
PARTICULATE FILTRATION EFFICIENCY (PFE)
The super high Particulate Filtration Efficiency (PFE) material filters >99% of particles greater than 0.1 microns. When securely fitted, the mask helps to provide an effective barrier to particulate matter from laser plumes and electrocautery procedures.
PFE measures the effectiveness of the mask material to filter particulate matter.
BREATHABILITY (DELTA P)
The mask design provides excellent breathability and low delta P (2.8) ensuring coolness and comfort even when worn for an extended period.
Delta P, also conducted by approved Independent testing facilities, is a test that measures the breathability of mask materials, ranking masks on comfort and coolness for the surgical mask wearer. The lower the figure, the cooler and more comfortable the mask.
FLUID RESISTANCE
The Super Fluid Resistant three-ply layer design provides optimum fluid resistance (120mmHg) Level 2 and (160mmHg) Level 3, thus minimising the risk of infection through strikethrough.
Fluid resistance is measured in accordance with ASTM F2101-15 | EN 14683:2014 standard test method for resistance of medical face masks to penetration by synthetic blood at 16.0kPa pressure.
International Standards:
- ISO 22609:2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)
- AS/NZS 4381:2015 'Single-use face masks for use in health care'
- ASTM F2100 - 19 Standard Specification for Performance of Materials Used in Medical Face Masks
- S. National Institute of Occupational Safety and Health (NIOSH) 42 CFR Part 84 Respiratory Protective Devices (in relation to products labelled with N-, R- and P- classification at 95, 99 and 99.9% filter efficiency)
- AS ISO 16900.3 2015 Respiratory protective devices - Methods of test and test equipment Determination of particle filter penetration
- AS NZS 1716:2012 Respiratory protective devices (in relation to products labelled with P1/P2/P3 class filter efficiency)
- EN 149:2001 + A1 Respiratory protective devices- Filtering half masks to protect against particle Requirements, testing, marking (in relation to products labelled with FFP1, FFP2 and FFP3 classification)
- GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying particle respirator (in relation products labelled with the filter element grades types KN and KP 90/95/100 filter elements)
- ISO 22609: 2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood
- EN 14683:2019 Medical face masks - Requirements and test methods
- AS NZS 1715:2009 Selection, use and maintenance of respiratory protective equipment
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Details:
- NOT INTENDED FOR HEALTHCARE USE
- Soft yet thick and durable
- Strong and hygienic cover
- Continuous roll
Code |
46827 |
Description |
FLUIDSHIELD Level 3 N95 Particulate Filter Respirator and Surgical Mask, Pouch-Style with Headbands, Small Size, Orange |
Packaging |
35 Units Per Box 6 Boxes Per Carton |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Features:
Multilayer Technology – Advanced multilayer technology providing protection against mechanically and thermally generated particulates including fluids, dusts, mists, fumes, and smoke.
- 3 Panel – Three panel design provides structural integrity, form fit seal, and optimal comfort. All three mask panels and seams have been independently tested and certified to AS 4381:2015 Level 3 – ISO 22609
- Bacterial Filtration Efficiency – Bacteria Filtration Efficiency (BFE) > 99%
- Fluid Resistance – Fluid Protection level 3, 160mmHg
- Proprietary Foam Nose Seal – Proprietary adjustable foam nose pad to ensure consistent optimum facial seal and reduce fogging of eyewear.
- Adapts to Most Faces – Versatile unisex fit suitable for a range of facial shapes and sizes. Effective for many “hard to fit” individuals.
- Fit Test Results – Specialized TRIDENT respirator seal attains unrivalled PortaCount fit testing results.
- Low Breathing Resistance – Low breathing resistance, maximizing wearer comfort, durability, and life of product.
- Use with Other PPE – Designed to be used in conjunction with other mandatory personal protective equipment.
- Latex Free – Latex Free to avoid the risk of developing allergies with repeated exposure.
- Batch Numbered and Individually Packed – Each mask is individually batch numbered and packaged for the ultimate traceability, portability, and hygiene.
Standards & Registrations:
Certified to:
- AS/NZS 1716:2012
- ID No. BMP 732382
- AS 4381: 2015 Level 3, 160 mmHg
- ID No. BMP 737354
ARTG 344154
Packaging:
Packaging |
1 Unit Per Pack |
|
20 Packs Per Box |
|
24 Boxes Per Carton |
Sizing:
Extra Small |
RTCFFP2XS |
Small |
RTCFFP2S |
Regular |
RTCFFP2 |
Regular Extended Length Head Straps |
RTCFFP2E |
XX Large |
RTCFFP2XXL |
How to Apply:
- Position the respirator in the palm of your hand with the nose strip at your fingertips, ensuring both head straps are untwisted over the back of your hand.
- Open both the top and bottom panels of the mask and make a bend in the foam nose seal. Place the lower panel under the chin and the upper panel with the foam nose seal over the nose bridge and underneath the eyes.
- Holding the respirator with one hand, position the top untwisted head strap to the crown of the head.
- Draw the lower untwisted head strap up and over the face to below the ears and back of the neck. DO Not Criss Cross Head straps.
- With both hands, mold the foam nose seal at the top of the mask to the nose bridge and cheeks ensuring a secure fit and seal.
- Perform a fit check (see fit check below). Cover the front of the respirator with both hands. Inhale and exhale sharply.
Fit Check List:
- If air leaks at the nose or cheek areas adjust the foam nose seal until a seal is achieved.
- If air leaks around the edge of the respirator adjust the head straps and reposition the mask until a seal is achieved.
- A successful fit check is when there is no air leakage.
- Always fit check before entering the work area.
- If a successful fit check cannot be achieved, remove, and refit the respirator.
- If you still cannot obtain a successful fit check, do not enter the work area.
How to Remove:
- The respirator may be contaminated. Touch only the head straps when removing.
- Pull the bottom strap over the top of the head.
- Pull the top strap over the top of the head.
- Pull the top strap over the top of the head.
- Dispose of respirator into the appropriate waste receptacle in accordance with site infection control and prevention policies.
- Wash and sanitize your hands thoroughly.
Important:
- A fit check must be performed prior to using your disposable respirator.
- Always read the disposable respirator wearer instructions.
- Should air leakage occur around the nose, adjust the foam nose/cheek support strip to eradicate the leakage & perform the above fit check.
- Should air leakage occur around the nose, adjust the foam nose/check support strip to eradicate the leakage & perform the above fit check.
- When an appropriate fit & seal cannot be achieved do not enter the hazardous environment & follow on-site policy referencing AS/NZS 1716:2012.
Note:
To achieve an optimum facial seal, the wearer should be clean-shaven. It is recommended the wearer be fit tested prior to use in accordance with AS/NZS 1715:2009 and/or onsite requirements. Training on the safe use and limitations of the disposable face mask must be performed in accordance with AS/NZS 1715:2009 section 2.4.
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
We're supporting the Starlight Children's Foundation by donating 1.5% back to the foundation for every box of 50 Surgical Masks sold.
Platinum Health Supply Group’s Range of surgical masks offer affordable and comfortable protection in all environments.
Intended to cover the user's mouth, nose and chin. Provides a physical barrier to prevent pathogenic microorganisms, body fluids, particulate matter, etc. from passing directly.
Product Size:
50pcs Per Box
Medical Compliance:
TGA Listing Number This product is listed as a Medical Device Included Class 1 (TGA available upon request.
General Features:
- Meets standard ASTM F2100-11 level 3 (bacterial filtration efficiency – BFE, differential pressure – Delta P)
- One size fits all
- Low breathing resistance for maximum comfort and prolonged wear
- Adjustable nose bridge for a personalised fit
- Non-sterile
- Single-use
- Retail packaging
- Latex-free
- Flame resistant
- 50 masks per box
General Information:
A surgical face mask is a disposable face mask worn over the nose and mouth to help protect against the inhalation of airborne particles and to help prevent the spread of unhealthy airborne particles. Surgical Masks are tested against their Bacteria Filtration Efficiency (BFE), Particular-Filtration Efficiency (PFE), Fluid Resistance Penetration (mmHg) and, Breathability (Delta P).
Unlike other cloth face coverings, a medical face mask is very carefully designed and manufactured to ensure that it remains effective at the prevention of spreading disease but not of minimising any respiratory distress a person may feel due to heavy pollution in the air.
Unlike general 3 Ply Face Masks, Surgical Masks are protective for General Public, Vulnerable Individuals, Medical and Health Care Workers, as well as Front Line Workers.
When wearing these mask’s, the user may limit their exposure to smoke, pollution, concrete/ sawdust, water/ virus particles and some vapours, and Bacteria.
Technical Information:
BACTERIAL FILTRATION EFFICIENCY (BFE)
With a Bacterial Filtration Efficiency (BFE) of greater than 99% for media greater than 3 microns, this mask provides superior protection from potential infection.
BFE is an independent test conducted by approved Independent testing facilities that measure the effectiveness of face mask materials to filter out bacteria.
PARTICULATE FILTRATION EFFICIENCY (PFE)
The super high Particulate Filtration Efficiency (PFE) material filters >99% of particles greater than 0.1 microns. When securely fitted, the mask helps to provide an effective barrier to particulate matter from laser plumes and electrocautery procedures.
PFE measures the effectiveness of the mask material to filter particulate matter.
BREATHABILITY (DELTA P)
The mask design provides excellent breathability and low delta P (≤2.8) ensuring coolness and comfort even when worn for an extended period.
Delta P, also conducted by approved Independent testing facilities, is a test that measures the breathability of mask materials, ranking masks on comfort and coolness for the surgical mask wearer. The lower the figure, the cooler and more comfortable the mask.
FLUID RESISTANCE
The Super Fluid Resistant three-ply layer design provides optimum fluid resistance (120mmHg) – Level 2 and (160mmHg) – Level 3, thus minimising the risk of infection through strikethrough.
Fluid resistance is measured in accordance with ASTM F2101-15 | EN 14683:2014 standard test method for resistance of medical face masks to penetration by synthetic blood at 16.0kPa pressure.
International Standards:
- ISO 22609:2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)
- AS/NZS 4381:2015 'Single-use face masks for use in health care'
- ASTM F2100 - 19 Standard Specification for Performance of Materials Used in Medical Face Masks
- S. National Institute of Occupational Safety and Health (NIOSH) 42 CFR Part 84 Respiratory Protective Devices (in relation to products labelled with N-, R- and P- classification at 95, 99 and 99.9% filter efficiency)
- AS ISO 16900.3 2015 Respiratory protective devices - Methods of test and test equipment Determination of particle filter penetration
- AS NZS 1716:2012 Respiratory protective devices (in relation to products labelled with P1/P2/P3 class filter efficiency)
- EN 149:2001 + A1 Respiratory protective devices- Filtering half masks to protect against particle – Requirements, testing, marking (in relation to products labelled with FFP1, FFP2 and FFP3 classification)
- GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying particle respirator (in relation products labelled with the filter element grades types KN and KP 90/95/100 filter elements)
- ISO 22609: 2004 Clothing for protection against infectious Sales Representatives - Medical face masks - Test method for resistance against penetration by synthetic blood
- EN 14683:2019 Medical face masks - Requirements and test methods
- AS NZS 1715:2009 Selection, use and maintenance of respiratory protective equipment
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Details:
- The 1860S healthcare respirator is designed to help provide respiratory protection for the wearer against certain airborne particles. It meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a disposable particulate respirator, it is intended to reduce wearer exposure to certain airborne particles including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials.
- The 1860S particulate respirator is a personal protective equipment (PPE) that is primarily intended to protect the health care workers by reducing exposure to harmful airborne particles which are small enough to be inhaled – typically particles less than 100 microns in size. These include airborne particles that may contain biological material e.g. Bacillus anthracis, Mycobacterium tuberculosis, mould and the virus that causes Severe Acute Respiratory Syndrome (SARS), and Influenza.
- Packaging: 20 respirators / box, 6 boxes / case
Proper selection, training and use are essential in order for the respirator to adequately protect the wearer from certain airborne contaminants.
Warning: Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of RPE. Details regarding performance and limitations are set out on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1715:2009 Standard. Misuse can result in sickness or death. For more information, see your Supervisor or contact an Occupational Hygienist, Safety professional or 3M TechAssist Helpline – Australia 1800 024 464 / New Zealand 0800 364 357.
Specifications:
Aerosol Type |
Non-Oil |
Assigned Protection Factor |
10 |
Boxes per Case |
6 |
Braided Comfort Strap |
Yes |
Brands |
3M |
Case Quantity |
120 |
Exhalation Valve |
No |
Features |
Advanced Electrostatic Media |
Filter Class |
N95 |
Flame Resistance (ASTM D2859-96) |
No |
Fluid Resistant (ASTM F1862) |
Yes |
Fluid and Splash Resistance |
80 mmHg |
Gas & Vapour Protection Type |
Particulate |
Natural Rubber Latex Components |
No |
Number per Box |
20 |
Product Colour |
Teal |
Product Type |
Healthcare Respirator |
Protection Level |
P2, N95 |
Respirator Size |
Small |
Respirator Style |
Cup |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
N95 3-Fold Respirator Australian Made provides excellent protection. It provides single-use, disposable respiratory protection to protect both the wearer and non-wearer from the transfer of microorganisms, body fluids, and particulate material.
- Surpassing American N95 Standard
- Features a 3 layer design to provide the maximum level of fluid resistance.
- P2/N95 respirator particulate respirator and provides high efficiency without valve
- Industrial quality disposable respirator mask with high-efficiency bacteria filtration
- Ideal for flu/pandemic outbreak protection
- Certified for AS/NZS 1716:2012 (certificate from Test Safe available), EN149:2001, and SANS 50149:2003
- Duckbill design with double elastic straps and a metal nose bridge.
- Low breathing resistance with high filtration efficiency.
- An adjustable nose piece and inner foam provide a custom seal.
- 160mmHg Surgical respirator
- BFE>99.7
- PFE>99.6
- Made in Australia
Features:
- 20 Per Pack
- Size: Universal
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Details:
The 1860 healthcare respirator is designed to help provide respiratory protection for the wearer against certain airborne particles. It meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a disposable particulate respirator, it is intended to reduce wearer exposure to certain airborne particles including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials.
The 1860 particulate respirator is a personal protective equipment (PPE) that is primarily intended to protect the health care workers by reducing exposure to harmful airborne particles which are small enough to be inhaled – typically particles less than 100 microns in size. These include airborne particles that may contain biological material e.g. Bacillus anthracis, Mycobacterium tuberculosis, mould and the virus that causes Severe Acute Respiratory Syndrome (SARS), and Influenza.
- Packaging: 20 respirators / box, 6 boxes / case
Proper selection, training and use are essential in order for the respirator to adequately protect the wearer from certain airborne contaminants.
Warning: Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of RPE. Details regarding performance and limitations are set out on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1715:2009 Standard. Misuse can result in sickness or death. For more information, see your Supervisor or contact an Occupational Hygienist, Safety professional or 3M TechAssist Helpline – Australia 1800 024 464 / New Zealand 0800 364 357.
Specifications:
Advanced Electrostatic Media |
Yes |
Aerosol Type |
Non-Oil |
Assigned Protection Factor |
10 |
Australia and New Zealand Compliance Standards |
N95 |
BFE |
less than 99 percent |
Boxes per Case |
6 |
Braided Comfort Strap |
Yes |
Brands |
3M |
Cartridge or Filter Included |
Yes |
Case Quantity |
120 |
Catalog Number |
1860 |
Exhalation Valve |
No |
Faceseal/Nosefoam |
Nosefoam |
Features |
Advanced Electrostatic Media |
Filter Class |
N95 |
Flame Resistance (ASTM D2859-96) |
No |
Flammability Rating |
Class 1 |
Fluid Resistant (ASTM F1862) |
Yes |
Fluid and Splash Resistance |
120 mmHg |
Gas & Vapour Protection Type |
Particulate |
Hazard Type |
Mould, Silica |
Model |
1860 |
Natural Rubber Latex Components |
No |
Number per Box |
20 |
Product Colour |
Teal |
Product Type |
Healthcare Respirator |
Protection Level |
N95, P2 |
Purpose |
Healthcare Respirator |
Recommended Application |
Grinding, Emergency & Pandemic Preparedness, Processing of Minerals, Sanding, Bagging, Agricultural Production, Textile Operations, Foundry Operation, Dry Chemical Handling, Petrochemical Manufacturing, Airborne Biological Particles |
Recommended Industry |
Health Care |
Respirator Size |
Standard |
Respirator Style |
Cup |
Strap Attachment Type |
Braided Comfort Strap |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
- The new head mounted N95 mask provides better protection. It can make you more comfortable and avoid ear damage.
- N95 Mask Breathable and comfortable lightweight design of N95 mask is made to be worn for long periods of time.
- Adjustable nose clip and elastic head wear help in obtaining a secure seal. Five layers of material design to ensure your safety.
- NIOSH Approved N95 certified for at least 95 percent filtration efficiency against certain non-oil-based particles.
Specifications:
Code |
N95FT-N040 |
Packaging |
20 Units Per Box |
20 Boxes Per Carton |
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
Features:
- Multilayer Technology – Advanced multilayer technology providing protection against mechanically and thermally generated particulates including fluids, dusts, mists, fumes, and smoke.
- 3 Panel – Three panel design provides structural integrity, form fit seal, and optimal comfort. All three mask panels and seams have been independently tested and certified to AS 4381:2015 Level 3 – ISO 22609
- Bacterial Filtration Efficiency – Bacteria Filtration Efficiency (BFE) > 99%
- Fluid Resistance – Fluid Protection level 3, 160mmHg
- Proprietary Foam Nose Seal – Proprietary adjustable foam nose pad to ensure consistent optimum facial seal and reduce fogging of eyewear.
- Adapts to Most Faces – Versatile unisex fit suitable for a range of facial shapes and sizes. Effective for many “hard to fit” individuals.
- Fit Test Results – Specialized TRIDENT respirator seal attains unrivalled PortaCount fit testing results.
- Low Breathing Resistance – Low breathing resistance, maximizing wearer comfort, durability, and life of product.
- Use with Other PPE – Designed to be used in conjunction with other mandatory personal protective equipment.
- Latex Free – Latex Free to avoid the risk of developing allergies with repeated exposure.
- Batch Numbered and Individually Packed – Each mask is individually batch numbered and packaged for the ultimate traceability, portability, and hygiene.
Standards & Registrations:
Certified to:
- AS/NZS 1716:2012
- ID No. BMP 732382
- AS 4381: 2015 Level 3, 160 mmHg
- ID No. BMP 737354
ARTG 344154
Packaging:
Packaging |
1 Unit Per Pack |
|
20 Packs Per Box |
|
24 Boxes Per Carton |
Sizing:
Extra Small |
RTCFFP2XS |
Small |
RTCFFP2S |
Regular |
RTCFFP2 |
Regular Extended Length Head Straps |
RTCFFP2E |
XX Large |
RTCFFP2XXL |
How to Apply:
- Position the respirator in the palm of your hand with the nose strip at your fingertips, ensuring both head straps are untwisted over the back of your hand.
- Open both the top and bottom panels of the mask and make a bend in the foam nose seal. Place the lower panel under the chin and the upper panel with the foam nose seal over the nose bridge and underneath the eyes.
- Holding the respirator with one hand, position the top untwisted head strap to the crown of the head.
- Draw the lower untwisted head strap up and over the face to below the ears and back of the neck. DO Not Criss Cross Head straps.
- With both hands, mold the foam nose seal at the top of the mask to the nose bridge and cheeks ensuring a secure fit and seal.
- Perform a fit check (see fit check below). Cover the front of the respirator with both hands. Inhale and exhale sharply.
Fit Check List:
- If air leaks at the nose or cheek areas adjust the foam nose seal until a seal is achieved.
- If air leaks around the edge of the respirator adjust the head straps and reposition the mask until a seal is achieved.
- A successful fit check is when there is no air leakage.
- Always fit check before entering the work area.
- If a successful fit check cannot be achieved, remove, and refit the respirator.
- If you still cannot obtain a successful fit check, do not enter the work area.
How to Remove:
- The respirator may be contaminated. Touch only the head straps when removing.
- Pull the bottom strap over the top of the head.
- Pull the top strap over the top of the head.
- Pull the top strap over the top of the head.
- Dispose of respirator into the appropriate waste receptacle in accordance with site infection control and prevention policies.
- Wash and sanitize your hands thoroughly.
Important:
- A fit check must be performed prior to using your disposable respirator.
- Always read the disposable respirator wearer instructions.
- Should air leakage occur around the nose, adjust the foam nose/cheek support strip to eradicate the leakage & perform the above fit check.
- Should air leakage occur around the nose, adjust the foam nose/check support strip to eradicate the leakage & perform the above fit check.
- When an appropriate fit & seal cannot be achieved do not enter the hazardous environment & follow on-site policy referencing AS/NZS 1716:2012.
Note:
To achieve an optimum facial seal, the wearer should be clean-shaven. It is recommended the wearer be fit tested prior to use in accordance with AS/NZS 1715:2009 and/or onsite requirements. Training on the safe use and limitations of the disposable face mask must be performed in accordance with AS/NZS 1715:2009 section 2.4.
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
"
Features:
- Multilayer Technology – Advanced multilayer technology providing protection against mechanically and thermally generated particulates including fluids, dusts, mists, fumes, and smoke.
- 3 Panel – Three panel design provides structural integrity, form fit seal, and optimal comfort. All three mask panels and seams have been independently tested and certified to AS 4381:2015 Level 3 – ISO 22609
- Bacterial Filtration Efficiency – Bacteria Filtration Efficiency (BFE) > 99%
- Fluid Resistance – Fluid Protection level 3, 160mmHg
- Proprietary Foam Nose Seal – Proprietary adjustable foam nose pad to ensure consistent optimum facial seal and reduce fogging of eyewear.
- Adapts to Most Faces – Versatile unisex fit suitable for a range of facial shapes and sizes. Effective for many “hard to fit” individuals.
- Fit Test Results – Specialized TRIDENT respirator seal attains unrivalled PortaCount fit testing results.
- Low Breathing Resistance – Low breathing resistance, maximizing wearer comfort, durability, and life of product.
- Use with Other PPE – Designed to be used in conjunction with other mandatory personal protective equipment.
- Latex Free – Latex Free to avoid the risk of developing allergies with repeated exposure.
- Batch Numbered and Individually Packed – Each mask is individually batch numbered and packaged for the ultimate traceability, portability, and hygiene.
Standards & Registrations:
Certified to:
- AS/NZS 1716:2012
- ID No. BMP 732382
- AS 4381: 2015 Level 3, 160 mmHg
- ID No. BMP 737354
ARTG 344154
Packaging:
Packaging |
1 Unit Per Pack |
|
20 Packs Per Box |
|
24 Boxes Per Carton |
Sizing:
Extra Small |
RTCFFP2XS |
Small |
RTCFFP2S |
Regular |
RTCFFP2 |
Regular Extended Length Head Straps |
RTCFFP2E |
XX Large |
RTCFFP2XXL |
How to Apply:
- Position the respirator in the palm of your hand with the nose strip at your fingertips, ensuring both head straps are untwisted over the back of your hand.
- Open both the top and bottom panels of the mask and make a bend in the foam nose seal. Place the lower panel under the chin and the upper panel with the foam nose seal over the nose bridge and underneath the eyes.
- Holding the respirator with one hand, position the top untwisted head strap to the crown of the head.
- Draw the lower untwisted head strap up and over the face to below the ears and back of the neck. DO Not Criss Cross Head straps.
- With both hands, mold the foam nose seal at the top of the mask to the nose bridge and cheeks ensuring a secure fit and seal.
- Perform a fit check (see fit check below). Cover the front of the respirator with both hands. Inhale and exhale sharply.
Fit Check List:
- If air leaks at the nose or cheek areas adjust the foam nose seal until a seal is achieved.
- If air leaks around the edge of the respirator adjust the head straps and reposition the mask until a seal is achieved.
- A successful fit check is when there is no air leakage.
- Always fit check before entering the work area.
- If a successful fit check cannot be achieved, remove, and refit the respirator.
- If you still cannot obtain a successful fit check, do not enter the work area.
How to Remove:
- The respirator may be contaminated. Touch only the head straps when removing.
- Pull the bottom strap over the top of the head.
- Pull the top strap over the top of the head.
- Pull the top strap over the top of the head.
- Dispose of respirator into the appropriate waste receptacle in accordance with site infection control and prevention policies.
- Wash and sanitize your hands thoroughly.
Important:
- A fit check must be performed prior to using your disposable respirator.
- Always read the disposable respirator wearer instructions.
- Should air leakage occur around the nose, adjust the foam nose/cheek support strip to eradicate the leakage & perform the above fit check.
- Should air leakage occur around the nose, adjust the foam nose/check support strip to eradicate the leakage & perform the above fit check.
- When an appropriate fit & seal cannot be achieved do not enter the hazardous environment & follow on-site policy referencing AS/NZS 1716:2012.
Note:
To achieve an optimum facial seal, the wearer should be clean-shaven. It is recommended the wearer be fit tested prior to use in accordance with AS/NZS 1715:2009 and/or onsite requirements. Training on the safe use and limitations of the disposable face mask must be performed in accordance with AS/NZS 1715:2009 section 2.4.
More Questions:
Still unsure if this product is right for your intended use? Get in contact with one of our Sales Representatives via the contact us page.
How can we help?

Live Chat

Call Us